AKAS SYRU 4004 - Syringe Pump

Press Esc to close
AKAS SYRU 4004 - Syringe pump

Product Description

AKAS SYRU 4004 is a front loading syringe infusion pump that can deliver critical care drugs to patients.

Can be used in Adult, Paediatric and Neonatal Patients. This has a drug library and Body Mass based Drug calculation

iso and ce certification


Product Description

AKAS SYRU 4004 is a front loading syringe infusion pump that can deliver critical care drugs to patients. Can be used in Adult, Paediatric and Neonatal Patients. This has a drug library and Body Mass based Drug calculation.


Product Highlights

  • Suitable for Cardiothoracic Patients
  • Rugged and Strong design for rough use
  • Compact (2.4 ltr) & Light weight(1.75kg)
  • 0.1 to 1200ml/hr flow rate
  • Long battery back up (up to 10 Hrs )
  • Dosage ramp up and tapper down function
  • Custom programmable mode to accept any brand of syringe
  • Auto / Purge bolus facility
  • Multiple safety alarm facility
  • Inline program during infusion

less weight syringe pump small & compactable
Anti Bolus function delivery line disconnected alarm function
single power cable porting multiple syringe pump option


Power Supply (I/P) AC 220V to 240V 50Hz
Battery 12V NiCd Battery
Battery Backup 10hrs @ 5ml.hr Flow rate on 50ml Syringe
Power Consumption 7 VA
Applicable Syringe 5ml, 10ml, 20ml, 30ml, 50ml &100ml Syringes from JMS, Braun, Dispovan, BD and Custom Programmable for any Brand of Syringe.
Automatic Syringe Detector Available
Custom Programmable Syringe Available
Flow Rate Range 0.1 - 200 ml/Hr 70ml/Hr (5ml Syringe)
0.1 - 300 ml/Hr 110ml/Hr (10ml Syringe)
0.1 - 500 ml/Hr 190ml/Hr (20ml Syringe)
0.1 - 700 ml/Hr 260ml/Hr (30ml Syringe)
0.1 - 1200 ml/Hr 400ml/Hr (50ml Syringe)
Infused Volume 0.1 - 999.9 ml
Elapsed Time Display of Elapsed time from 00:01 to 99:59 Hrs
Modes Drug Library mode, Flow Rate only, Flow Rate & Target volume, Flow Rate & Target Time Target volume and target time
Bolus Purge Bolus & Auto Bolus
Bolus Flow Rate 10 - 200 ml/Hr 70 ml/Hr (5ml Syringe)
10 - 300 ml/Hr 110 ml/Hr (10ml Syringe)
10 - 500 ml/Hr 190 ml/Hr (20ml Syringe)
10 - 700 ml/Hr 260 ml/Hr (30ml Syringe)
10 - 1200 ml/Hr 400 ml/Hr (50ml Syringe)
Bolus Volume 0.1ml to 10 ml in 0.1 ml increments
Dosage Taper Up/ Down(Sequential Mode) Available with 10 different programs
KVO 0.1ml/Hr to 9.9ml/Hr in 0.1 ml increment
Occlusion Pressure 10 steps selection (OFF to 9 Levels)
Alarms tAr.1 - Target Volume reached
tAr.2 - Target time reached
End - End of Syringe
PCA.d - PCA Probe disconnected
occL - Occlusion
OFF - Battery discharged
AL 1 - Syringe holder disturbed during infusion
AL 2 - Syringe Disengaged while running
AL 3 - Motor unable to drive
AL 4 - Mains to Battery F/R High reduce F/R 200
AL 5 - AC Power over limit
AL 6 - AC Voltage below 215
AL 9 - Syringe not engage
Audio/Visual Indication Target reached (time or volume), End of syringe, PCA probe & Alarms Disconnected, Occlusion, Battery discharged, Motor unable to drive, Syringe not engaged, Near Empty, Battery low, Operation on mains / battery
Display Four 7 segment Display
PCA (Optional) PCA dose can be preset from 0.1 to 10ml. Minimum locking time interval between two doses, Time interval from 0 -24Hrs in steps of 1 min, Delivered and non delivered doses display
Accuracy Mechanical Accuracy ±1%; Including Syringe ± 3%
Safety Testing EN 60601-1, EN 60601-1-2, EN 60601-1-6, EN 60601-1-8, EN 60601-2-24
Certification ISO 9001:2008; ISO 13485:2003; CE
Dimension 170 x 107 x 135 ( L x B x W)
Space Occupied 2.4 ltrs
Weight 1.75kg

Related Products